{"product_id":"rfd400h","title":"RFD400H","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eSize:\u003c\/strong\u003e\u003cspan\u003e Carton of (30) 1 lb. bags\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan data-teams=\"true\"\u003e\u003cspan dir=\"ltr\" class=\"ui-provider a b c d e f g h i j k l m n o p q r s t u v w x y z ab ac ae af ag ah ai aj ak\"\u003eRFD400H fibers are made of Polyvinyl Alcohol (PVA) and have a denier of 360, specifically designed for use in fiber-reinforced concrete (FRC). These fibers enhance the concrete’s flexural strength, impact resistance, and abrasion resistance. They also help prevent balling and improve distribution within the mix. Additionally, RFD400H fibers control shrinkage and temperature-induced cracking. They bond at a molecular level through hydrogen bonding, forming a multi-dimensional network that boosts both tensile strength (240 ksi or 1600 MPa) and flexural strength in the concrete.\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cem\u003eMeets the requirements of \u003ca title=\"Standard Specification for Fiber-Reinforced Concrete\" href=\"https:\/\/www.astm.org\/Standards\/C1116.htm\"\u003eASTM C-1116, Section 4.1.3\u003c\/a\u003e and \u003ca title=\"AC32 - Concrete with Synthetic Fibers\" href=\"https:\/\/icc-es.org\/acceptance-criteria\/ac32\/\" target=\"_blank\"\u003eAC-32\u003c\/a\u003e\u003c\/em\u003e at 1.0 lb (0.45 kg) per CY.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cem\u003e\u003cstrong\u003eBulk pricing available, \u003ca href=\"https:\/\/nycon-fibers.myshopify.com\/apps\/wpdapp\" target=\"_blank\"\u003econtact us\u003c\/a\u003e for a quote.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003eSpecifications\u003c\/h5\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-qodj\"\u003eConfiguration\u003c\/th\u003e\n\u003cth class=\"tg-0fug\"\u003e\u003cspan style=\"font-weight: normal;\"\u003eMonofilament\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2mkc\"\u003eFineness\u003c\/td\u003e\n\u003ctd class=\"tg-sv3f\"\u003e400 dtex ± 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-qodj\"\u003eFilament Diameter\u003c\/td\u003e\n\u003ctd class=\"tg-0fug\"\u003e360 Denier (200 Microns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2mkc\"\u003eFiber Length\u003c\/td\u003e\n\u003ctd class=\"tg-sv3f\"\u003e12-18mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-qodj\"\u003eSpecific Gravity\u003c\/td\u003e\n\u003ctd class=\"tg-0fug\"\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2mkc\"\u003eTensile Strength\u003c\/td\u003e\n\u003ctd class=\"tg-sv3f\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan data-teams=\"true\"\u003e\u003cspan class=\"ui-provider a b c d e f g h i j k l m n o p q r s t u v w x y z ab ac ae af ag ah ai aj ak\" dir=\"ltr\"\u003e1404 MPa (203 KSI)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-qodj\"\u003eMelting Point\u003c\/td\u003e\n\u003ctd class=\"tg-0fug\"\u003eOver 392° F (200° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2mkc\"\u003eElongation at Break\u003c\/td\u003e\n\u003ctd class=\"tg-sv3f\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan data-teams=\"true\"\u003e\u003cspan dir=\"ltr\" class=\"ui-provider a b c d e f g h i j k l m n o p q r s t u v w x y z ab ac ae af ag ah ai aj ak\"\u003e7.3 %\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-qodj\"\u003eColor\u003c\/td\u003e\n\u003ctd class=\"tg-0fug\"\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2mkc\"\u003eAlkali Resistance\u003c\/td\u003e\n\u003ctd class=\"tg-sv3f\"\u003eExcellent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-qodj\"\u003eConcrete Surface\u003c\/td\u003e\n\u003ctd class=\"tg-0fug\"\u003eNot Fuzzy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-2mkc\"\u003eCorrosion Resistance\u003c\/td\u003e\n\u003ctd class=\"tg-sv3f\"\u003eExcellent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5 class=\"p1\"\u003eInstructions\u003c\/h5\u003e\n\u003cp\u003eRFD400H can be added directly to the mixing system during or after the batching of the ingredients and mixed at high speed for a minimum of five minutes. Additional mixing does not adversely affect the distribution or overall performance of PVA.\u003c\/p\u003e\n\u003cp\u003eThe addition of \u003cmeta charset=\"utf-8\"\u003eRFD400H at the normal or high dosage rate does not require any mix design or application changes. A water reducer or super-plasticizer is recommended in concrete products where improved workability and finishability are desired. PVA reinforcing fiber acts with a molecular bond in the concrete with a multi-dimensional fiber network. It does not affect curing process chemically.\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003eApplications\u003c\/h5\u003e\n\u003cdiv class=\"col-lg-6 col-md-7 col-sm-6\"\u003e\n\u003cp\u003eStucco, Shotcrete, Precast and al\u003cspan data-teams=\"true\"\u003e\u003cspan dir=\"ltr\" class=\"ui-provider a b c d e f g h i j k l m n o p q r s t u v w x y z ab ac ae af ag ah ai aj ak\"\u003el UHPC\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5 class=\"p1\"\u003e\u003cb\u003eDocumentation\u003c\/b\u003e\u003c\/h5\u003e\n\u003cul class=\"ul1\"\u003e\n\u003cli class=\"li1\"\u003e\n\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0088\/0764\/5299\/files\/RFD400H.pdf?v=1763066591\" target=\"_blank\"\u003e📄 RFD400H Data Sheet\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli class=\"li1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0088\/0764\/5299\/files\/SDS_PVA.pdf?v=1776694165\" target=\"_blank\" rel=\"noopener\"\u003e📄 RFD400H SDS Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"PVA Fiber","offers":[{"title":"Default Title","offer_id":42079298224243,"sku":null,"price":294.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0088\/0764\/5299\/files\/RFD400H.jpg?v=1763066035","url":"https:\/\/nycon.com\/products\/rfd400h","provider":"Nycon","version":"1.0","type":"link"}